Cásanna Molta Cumhachta & Úsáide Molta
|
Fadtréimhsim |
Iarratais Molta |
|
20-50kva |
Oifigí beaga, túir teileachumarsáide, cumhacht tuaithe |
|
75–150kva |
Foirgnimh tráchtála, clinicí, scoileanna |
|
200–400kva |
Gléasraí Tionsclaíocha, Láithreáin Tógála |
|
500–800kva |
Ionaid sonraí, ospidéil, monarchana |
|
1000–2000kva |
Stáisiúin Chumhachta, Mianadóireacht, Móra - Cúltaca Scála |
Sonraíochtaí teicniúla
|
Múnla Múnla |
Cumhacht fuireachais |
Príomhchumhacht |
Samhail innill |
Voltas |
Minicíocht |
Tíopáil |
|
C25 |
25kva |
23kva |
4BT3.9-G1 |
230/400V |
50Hz |
Adh/oscailte/leantóir |
|
C100 |
100kva |
90kva |
6bt5.9-g2 |
230/400V |
50Hz |
Adh/oscailte/leantóir |
|
C250 |
250kva |
225kva |
NTA855-G1B |
230/400V |
50Hz |
Adh/oscailte/leantóir |
|
C500 |
500kva |
450kva |
KTA19-G3 |
230/400V |
50Hz |
Ciúin/oscailte |
|
C1000 |
1000kva |
900kva |
KTA38-G9 |
400/690V |
50Hz |
Coimeádna |
Cén fáth a roghnaíonn tú ár dtacar gineadóir Cummins?
✔ Faoi thiomáint ag innill bhunaidh Cummins
Feidhmíocht chruthaithe, saol fada seirbhíse, agus dea -cháil dhomhanda.
✔ Raon cumhachta leathan
Ó 20kva go 2000kva - oiriúnach do thithe beaga go monarchana móra.
✔ Roghanna ciúin & coimeádta
Ceannbhrat roghnach Soundproof nó coimeádán ISO 20ft/40ft le haghaidh úsáide lasmuigh.
✔ Córas rialaithe cliste
Feistithe le rialtóirí Deepsea/ SmartGen/ Comap, ATS roghnach.
✔ Global tar éis {- Tacaíocht Díolacháin
Inúsáidte trí chummins Global Network i dtíortha 190+.
✔ CE/ ISO Deimhnithe & Onnmhairiú Réidh
Comhlíonann sé go hiomlán le caighdeáin an AE, atá oiriúnach don Afraic, don Mheánoirthear, don Áise Thoir Theas.
Samhlacha atá ar Fáil
- Minicíocht:50Hz/ 60Hz
- Voltas:230/400V, 380/220V, 415V, 480V, 690V
- Cineálacha:Cineál Oscailte/ Cineál/ Leantóir/ Coimeádán Oscailte
- Roghanna branda do ailtire:Stamford, Leroy Somer, Marathon
- Rialaitheoir:Deepsea/ Comap/ SmartGen
- Roghnach:Painéal ATS, córas comhthreomhar, monatóireacht cianda, saincheapadh umar breosla

Cta
Faigh luachan saor in aisce inniu - Déan teagmháil linn le haghaidh bileoga sonraí, praghsála agus loingseoireachta![Foirm Teagmhála]nóbetty@wfbofapower.com


Clibeanna Te: Socraigh Gineadóir Cummins, Soláthraithe Socraithe Gineadóir Cummins na Síne, Monarcha
Tábla Paraiméadair Cumhachta Cummins Cummins
| Samhail aonaid | Cumhacht Aschuir (KW) | Sruth leictreach (a) | Cineál innill díosail | Líon na sorcóirí | Trastomhas Bore * stróc (mm) | Toirt sceite (l) | Ráta ídithe breosla g/kw.h | Méid an aonaid (mm) l*w*h | Méid an aonaid (kg) | |
| KW | KVA | |||||||||
| 15GF | 15 | 18.75 | 27 | 4B3.9-G2 | 4 | 102*120 | 3.9 | 208 | 1650*720*1200 | 700 |
| 20GF | 20 | 25 | 36 | 4B3.9-G2 | 4 | 102*120 | 3.9 | 208 | 1650*720*1200 | 700 |
| 24GF | 24 | 30 | 43.2 | 4BT3.9-G2 | 4 | 102*120 | 3.9 | 208 | 1700*720*1200 | 710 |
| 30GF | 30 | 37.5 | 54 | 4BT3.9-G2 | 4 | 102*120 | 3.9 | 208 | 1700*720*1200 | 800 |
| 40GF | 40 | 50 | 72 | 4BTA3.9-G2 | 4 | 102*120 | 3.9 | 210 | 1800*750*1200 | 920 |
| 50GF | 50 | 62.5 | 90 | 4BTA3.9-G2 | 4 | 102*120 | 3.9 | 210 | 1800*750*1200 | 950 |
| 64GF | 64 | 80 | 115.2 | 4BTA3.9-G11 | 4 | 102*120 | 3.9 | 210 | 1850*800*1300 | 1000 |
| 80GF | 80 | 100 | 144 | 6bt5.9-g2 | 6 | 102*120 | 5.9 | 210 | 2250*800*1300 | 1250 |
| 100gf | 100 | 125 | 180 | 6bta5.9-g2 | 6 | 102*120 | 5.9 | 207 | 2300*800*1300 | 1300 |
| 120GF | 120 | 150 | 216 | 6BTAA5.9-G2 | 6 | 102*120 | 5.9 | 207 | 2300*830*1300 | 1350 |
| 150GF | 150 | 187.5 | 270 | 6cta8.3-g2 | 6 | 114*135 | 8.3 | 207 | 2400*970*1500 | 1600 |
| 180GF | 180 | 225 | 324 | 6ctaa8.3-g2 | 6 | 114*135 | 8.3 | 207 | 2400*970*1500 | 1700 |
| 200GF | 200 | 250 | 360 | 6ltaAa8.9-g2 | 6 | 114*145 | 8.9 | 207 | 2600*970*1500 | 2000 |
| 220GF | 220 | 275 | 396 | 6ltaAa8.9-G3 | 6 | 114*145 | 8.9 | 203 | 2600*970*1500 | 2000 |
| 320GF | 320 | 400 | 576 | 6ZTAA13-G3 | 6 | 114*145 | 13 | 202 | 2900*1200*1750 | 3000 |
| 400GF | 400 | 500 | 720 | 6ZTAA13-G4 | 6 | 114*145 | 13 | 202 | 2900*1200*1750 | 3000 |
| 400GF | 400 | 500 | 720 | QSZ13-G2 | 6 | 130*163 | 13 | 201 | 3100*1250*1800 | 3100 |
| 450GF | 450 | 562.5 | 810 | QSZ13-G3 | 6 | 130*163 | 13 | 201 | 3100*1250*1800 | 3100 |
| 200gf | 200 | 250 | 360 | NT8555-GA | 6 | 140*152 | 14 | 206 | 3000*1050*1750 | 2600 |
| 200GF | 200 | 250 | 360 | MTA11-G2 | 6 | 140*152 | 14 | 206 | 3000*1050*1750 | 2700 |
| 250GF | 250 | 312.5 | 450 | NTA855-G1A | 6 | 140*152 | 14 | 207 | 3100*1050*1750 | 2900 |
| 280gf | 280 | 350 | 504 | MTAA11-G3 | 6 | 125*147 | 11 | 210 | 3100*1050*1750 | 2900 |
| 280gf | 280 | 350 | 504 | NTA855-G1B | 6 | 140*152 | 14 | 206 | 3100*1050*1750 | 2950 |
| 300GF | 300 | 375 | 540 | NTA855-G2A | 6 | 140*152 | 14 | 206 | 3200*1050*1750 | 3000 |
| 350GF | 350 | 437.5 | 630 | NTAA855-G7A | 6 | 140*152 | 14 | 205 | 3300*1250*1850 | 3200 |
| 400GF | 400 | 500 | 720 | KTA19-G3A | 6 | 159*159 | 19 | 206 | 3300*1400*1970 | 3700 |
| 450GF | 450 | 562.5 | 810 | KTA19-G4 | 6 | 159*159 | 19 | 206 | 3300*1400*1970 | 3900 |
| 500gf | 500 | 625 | 900 | KTA19-G8 | 6 | 159*159 | 19 | 206 | 3500*1500*2000 | 4200 |
| 550GF | 550 | 687.5 | 990 | Ktaa19-g6a | 6 | 159*159 | 19 | 206 | 3600*1500*2000 | 4800 |
| 600gf | 600 | 750 | 1080 | KT38-GA | 12 | 159*159 | 38 | 206 | 4300*1700*2350 | 7000 |
| 650gf | 650 | 812.5 | 1170 | KTA38-G2 | 12 | 159*159 | 38 | 206 | 4300*1700*2350 | 7500 |
| 700gf | 700 | 875 | 1260 | KTA38-G2B | 12 | 159*159 | 38 | 206 | 4400*1750*2350 | 8000 |
| 800gf | 800 | 1000 | 1440 | KTA38-G2A | 12 | 159*159 | 38 | 206 | 4500*1750*2350 | 8200 |
| 900GF | 900 | 1125 | 1620 | KTA38-G5 | 12 | 159*159 | 38 | 208 | 4500*1800*2350 | 8800 |
| 1000GF | 1000 | 1250 | 1800 | KTA38-G9 | 12 | 159*159 | 38 | 208 | 4500*1800*2350 | 9200 |
| 1100gf | 1100 | 1375 | 1980 | KTA50-G3 | 16 | 159*159 | 50 | 205 | 5300*2080*2500 | 10000 |
| 1200gf | 1200 | 1500 | 2160 | KTA50-G8 | 16 | 159*159 | 50 | 205 | 5700*2280*2500 | 10500 |
| 1440gf | 1440 | 1800 | 2592 | QSK50G7 | 16 | 159*190 | 60 | 205 | 5700*2280*2500 | 12500 |
| 1680gf | 1680 | 2100 | 3024 | QSK60G3 | 16 | 159*190 | 60 | 205 | 5700*2280*2500 | 13000 |
| 1760gf | 1760 | 2200 | 3168 | QSK60G4 | 16 | 159*190 | 60 | 205 | 5800*2300*2600 | 13500 |
| 1840gf | 1840 | 2300 | 3312 | QSK60G13 | 16 | 159*190 | 60 | 205 | 5800*2300*2600 | 13500 |