Ar fáil i gcineál oscailte, ceannbhrat adh, leantóir - suite, agus cumraíochtaí coimeádta.
Sonraíochtaí teicniúla (samhlacha samplacha)
|
Múnla Múnla |
Cumhacht fuireachais |
Príomhchumhacht |
Samhail innill |
Voltas |
Minicíocht |
Cumraíocht |
|
W30 |
30kva |
27kva |
WP2.3D33E200 |
230/400V |
50Hz |
Ciúin / oscailte |
|
W150 |
150kva |
135kva |
WP6D152E200 |
230/400V |
50Hz |
Ciúin / leantóir |
|
W500 |
500kva |
450kva |
12M26D660E200 |
230/400V |
50Hz |
Coimeádna |
|
W1000 |
1000kva |
900kva |
12M33D1100E200 |
400/690V |
50Hz |
Coimeádna |
|
W2000 |
2000kva |
1800kva |
16M33D2100E200 |
400/690V |
50Hz |
Coimeádna |
|
W3300 |
3300kw |
3000kw |
16M55D3300E200 |
400/690V |
50Hz |
Coimeádna |
|
W4125 |
4125kva |
3750kva |
16M55D4125E200 |
400/690V |
50Hz |
Coimeádna |
Saincheaptha 60Hz, ard - voltas, oibriú comhthreomhar, agus roghanna monatóireachta cianda ar fáil.
Príomhghnéithe de ghineadóirí díosail Weichai
- Fíor -innill weichai{- Cobhsaíocht chruthaithe, ardéifeachtúlacht, agus saol oibríochtúil fada.
- Ultra - raon cumhachta leathan{- ó 25KVA go 4125KVA, ag bualadh le héilimh chumhachta scála beag go mega -.
- Cumraíochtaí durable & solúbtha{- Cineál oscailte, ceannbhrat ciúin, leantóir, agus aonaid coimeádta.
- Roghanna Rialaithe Cliste{- Deepsea, comap, nó rialtóirí SmartGen comhtháite.
- Easpórtáil - Comhlíonadh Réidh{- CE / ISO Deimhnithe, atá deartha le haghaidh caighdeáin mhargaidh dhomhanda.

Glao ar Ghníomh
Déan teagmháil linn inniu le haghaidh Praghsáil, Sonraíochtaí, nó Sonraí Saincheaptha atá leagtha síos ag Weichai Gineadóir.


Clibeanna Te: Socraigh Gineadóir Weichai, Soláthraithe Socraithe Gineadóir na Síne Weichai, Monarcha
Liosta Paraiméadair de Thábla Paraiméadair Socraithe Gineadóir Weichai
| Samhail aonaid | Cumhacht Aschuir (KW) | Sruth leictreach (a) | Cineál innill díosail | Líon na sorcóirí | Trastomhas Bore * stróc (mm) | Toirt sceite (l) | Cumas ola bealaithe (L) | Ráta ídithe breosla/kw.h | Méid an Aonaid (mm) L × W × H. | Meáchan aonaid kg | |
| KW | KVA | ||||||||||
| Sraith Yangchai Cumhacht Weichai | |||||||||||
| 16GF | 16 | 20 | 28.8 | WP2.1D18E2 | 4 | 85*92 | 2.09 | 12 | 235 | 1500*630*1100 | 650 |
| 20GF | 20 | 25 | 36 | WP2.5D22E2 | 4 | 90*100 | 2.54 | 12 | 235 | 1550*630*1150 | 660 |
| 30GF | 30 | 37.5 | 54 | Wp3.9d33e2 | 4 | 102*118 | 3.86 | 12 | 235 | 1600*650*1180 | 800 |
| 34GF | 34 | 42.5 | 61.2 | WP4.3D38E2 | 4 | 105*125 | 4.33 | 12 | 235 | 1600*650*1180 | 800 |
| 40GF | 40 | 50 | 72 | WP4.6D44E2 | 4 | 108*125 | 4.58 | 12 | 235 | 1600*650*1180 | 820 |
| 48gf | 48 | 60 | 86.4 | WP4.1D50E2 | 4 | 105*118 | 4.09 | 12 | 215 | 1700*600*1100 | 900 |
| 58gf | 58 | 72.5 | 104.4 | WP4.3D61E2 | 4 | 108*118 | 4.32 | 12 | 210 | 1800*650*1200 | 950 |
| Weichai Power Deutsch | |||||||||||
| 50GF | 50 | 62.5 | 90 | WP4D66E200 | 4 | 105*130 | 4.5 | 28 | 198 | 1950*950*1340 | 1100 |
| 60GF | 60 | 75 | 108 | WP4D66E200 | 4 | 105*130 | 4.5 | 28 | 198 | ||
| 80GF | 80 | 100 | 144 | WP4D100E200 | 4 | 105*130 | 4.5 | 28 | 198 | 2200*920*1340 | 1250 |
| 90GF | 90 | 112.5 | 162 | WP4D100E200 | 4 | 105*130 | 4.5 | 28 | 198 | ||
| 90GF | 90 | 112.5 | 162 | WP4D108E200 | 4 | 105*130 | 4.5 | 28 | 198 | 2200*920*1340 | 1250 |
| 100gf | 100 | 125 | 180 | WP4D108E200 | 4 | 105*130 | 4.5 | 28 | 198 | ||
| 100gf | 100 | 125 | 180 | WP6D132E200 | 6 | 105*130 | 6.75 | 35 | 198 | 2470*930*1450 | 1550 |
| 120GF | 120 | 150 | 216 | WP6D132E200 | 6 | 105*130 | 6.75 | 35 | 198 | ||
| 120GF | 120 | 150 | 216 | WP6D152E200 | 6 | 105*130 | 6.75 | 35 | 198 | 2470*930*1450 | 1620 |
| 132gf | 132 | 165 | 237.6 | WP6D152E200 | 6 | 105*130 | 6.75 | 39 | 198 | ||
| Cumhacht weichai gorm | |||||||||||
| 180GF | 150 | 187.5 | 270 | WP10D200E200 | 6 | 126*130 | 9.726 | 35 | 195 | 2600*950*1400 | 1650 |
| 200GF | 200 | 250 | 360 | WP10D238E200 | 6 | 126*130 | 9.726 | 35 | 195 | 2750*970*1800 | 2100 |
| 240GF | 220 | 275 | 396 | WP10D264E200 | 6 | 126*130 | 9.726 | 35 | 195 | 2800*970*1800 | 2200 |
| 280gf | 250 | 312.5 | 450 | WP12D317E200 | 6 | 126*155 | 11.596 | 38 | 195 | 2850*970*1800 | 2300 |
| 300GF | 300 | 375 | 540 | WP13D385E200 | 6 | 127*165 | 12.54 | 48 | 195 | 2900*970*1800 | 2400 |
| 350GF | 300 | 375 | 540 | WP13D385E200 | 6 | 127*165 | 12.54 | 48 | 195 | 2950*970*1800 | 2500 |
| 400GF | 400 | 500 | 1010 | WHM6160D518 | 6 | 160*200 | 15.9 | 65 | 195 | 3850*1340*1955 | 5700 |
| Cumhacht weichai | |||||||||||
| 440GF | 440 | 550 | 792 | 6M26D484E200 | 6 | 150*150 | 15.9 | 65 | 195 | 3500*1500*2000 | 4800 |
| 880gf | 880 | 1100 | 1584 | 12M26D968E200 | 12 | 150*150 | 31.8 | 120 | 195 | 4500*1700*2450 | 8500 |
| 1000GF | 1000 | 1250 | 1800 | 12M33D1210E200 | 12 | 150*185 | 39.2 | 146 | 210 | 4800*1800*2450 | 9500 |