Iarratais tipiciúla |
|
25–90kva |
Tithe, oifigí beaga, túir teileachumarsáide, cúltaca tuaithe |
|
100–250kva |
Óstáin, scoileanna, clinicí, ollmhargaí |
|
300–600kva |
Monarchana, stórais, suíomhanna tógála |
|
800–1500kva |
Ionaid sonraí, coimpléisc tráchtála mhóra |
|
1600–2500KVA |
Páirceanna tionsclaíocha, oibríochtaí mianadóireachta, cúltaca fóntais |
Ar fáil i gcineál oscailte, ceannbhrat ciúin, leantóir - suite, agus dearaí coimeádta.
Sonraíochtaí teicniúla (samhlacha samplacha)
|
Múnla Múnla |
Cumhacht fuireachais |
Príomhchumhacht |
Samhail innill |
Voltas |
Minicíocht |
Cumraíocht |
|
S30 |
30kva |
27kva |
SC4H95D2 |
230/400V |
50Hz |
Ciúin / oscailte |
|
S150 |
150kva |
135kva |
SC7H230D2 |
230/400V |
50Hz |
Ciúin / leantóir |
|
S500 |
500kva |
450kva |
SC15G630D2 |
230/400V |
50Hz |
Coimeádna |
|
S1000 |
1000kva |
900kva |
SC25G3100D2 |
400/690V |
50Hz |
Coimeádna |
|
S2000 |
2000kw |
1800kw |
SC33G4200D2 |
400/690V |
50Hz |
Coimeádna |
|
S2500 |
2500kva |
2250kva |
SC33G5250D2 |
400/690V |
50Hz |
Coimeádna |
Custom 60Hz, ard - voltas, oibriú comhthreomhar, agus roghanna ATS ar fáil.
Príomhghnéithe de ghineadóirí díosail SDEC
- Faoi thiomáint ag innill bhunaidh SDEC{- Iontaofacht chruthaithe, saol fada seirbhíse, agus éifeachtúlacht breosla den scoth.
- Clúdach cumhachta leathan{- ó 25kva go 2500kva, ag clúdach gnó beag go tionscal trom.
- Cumraíochtaí solúbtha{- Cineál oscailte, ceannbhrat ciúin, leantóir, agus dearaí coimeádta.
- Roghanna Rialaithe Cliste{- DeepSea, Comap, nó SmartGen Rialaitheoirí atá ar fáil.
- Easpórtáil - Comhlíonadh Réidh{- CE / ISO Deimhnithe, atá deartha le haghaidh margaí domhanda.

Glao ar Ghníomh
Déan teagmháil linn inniu le haghaidh praghsáil, sonraíochtaí, nó roghanna saincheaptha SDEC.


Clibeanna Te: Socraigh Gineadóir SDEC, Soláthraithe Socraithe Gineadóir SDEC na Síne, Monarcha
Tábla Paraiméadair Socraithe Gineadóir Cumhachta SDEC
| Samhail genset | Cumhacht (KW) | Aschur Reatha (A) | Samhail innill | Líon na sorcóirí | Bore * stróc (mm) | Díláithriú (L) | Ídiú breosla (g/kw.h) | Toise (L × W × H MM) | Meáchan aonaid (kg) | |
| KW | KVA | |||||||||
| BF-50GF | 50 | 62.5 | 90 | SC4H95D2 | 4 | 105*124 | 4.3 | 204 | 2650*1100*1700 | 2300 |
| BF-75GF | 75 | 93.75 | 135 | SC4H115D2 | 4 | 105*124 | 4.3 | 204 | 2650*1100*1700 | 2300 |
| BF-100GF | 100 | 125 | 180 | SC4H160D2 | 4 | 105*124 | 4.3 | 198 | 2500*900*1500 | 2000 |
| BF-120GF | 120 | 150 | 216 | SC4H180D2 | 4 | 105*124 | 4.3 | 198 | 2220*840*1190 | 1200 |
| BF-150GF | 150 | 187.5 | 270 | SC7H230D2 | 6 | 105*124 | 6.5 | 199 | 2700*900*1750 | 2300 |
| BF-170GF | 170 | 212.5 | 306 | SC7H250D2 | 6 | 105*124 | 6.5 | 195 | 2900*1100*1600 | 2480 |
| BF-180GF | 180 | 225 | 324 | SC8D280D2 | 6 | 114*135 | 8.27 | 200 | 2800*900*1800 | 2400 |
| BF-200GF | 200 | 250 | 360 | SC9D310D2 | 6 | 114*144 | 8.82 | 195 | 2900*1200*1800 | 2500 |
| BF-220GF | 220 | 275 | 396 | SC9D340D2 | 6 | 114*144 | 8.82 | 195 | 3000*1200*1800 | 2600 |
| BF-250GF | 250 | 312.5 | 450 | SC13G355D2 | 6 | 135*150 | 12.88 | 200 | 3000*1300*1800 | 2800 |
| BF-250GF | 250 | 312.5 | 450 | SC13G420D2 | 6 | 135*150 | 12.88 | 200 | 3000*1300*1800 | 2800 |
| BF-300GF | 300 | 375 | 540 | SC13G420D2 | 6 | 135*150 | 12.88 | 200 | 3000*1300*1800 | 2800 |
| BF-300GF | 300 | 375 | 540 | SC12E460D2 | 6 | 128*153 | 11.8 | 192 | 3100*1350*1900 | 3200 |
| BF-320GF | 320 | 400 | 576 | SC15G500D2 | 6 | 135*165 | 14.16 | 200 | 3200*1350*1950 | 3500 |
| BF-350GF | 350 | 437.5 | 630 | SC15G500D2 | 6 | 135*165 | 14.16 | 200 | 3200*1350*1950 | 3500 |
| BF-400GF | 400 | 500 | 720 | SC25G610D2 | 12 | 135*150 | 25.8 | 202 | 3400*1500*1950 | 4200 |
| BF-450GF | 450 | 562.5 | 810 | SC25G690D2 | 12 | 135*150 | 16.8 | 202 | 3500*1500*1950 | 4500 |
| BF-500GF | 500 | 625 | 900 | SC27G755D2 | 12 | 135*155 | 26.6 | 202 | 3500*1500*1950 | 4800 |
| BF-550GF | 550 | 687.5 | 990 | SC27G830D2 | 12 | 135*155 | 26.6 | 202 | 3600*1600*2000 | 5000 |
| BF-600GF | 600 | 750 | 1080 | SC27G900D2 | 12 | 135*155 | 26.6 | 202 | 3650*1600*2000 | 5000 |
| BF-660GF | 660 | 825 | 1188 | SC33W990D2 | 6 | 180*215 | 32.8 | 205 | 4000*1600*2200 | 5200 |
| BF-800GF | 800 | 1000 | 1440 | SC33W1150D | 6 | 180*215 | 32.8 | 205 | 4000*1600*2200 | 5200 |